HV Cast Resin Transformers (Standard Series)   Specification
  1. Scope of application
    This specification includes the following rated capacities, design, manufacturing, testing, handling, installation, and warranty of high-permeability directional silicon steel sheet iron core cast resin transformers for indoor use.
  2. Applicable standards
    Relevant manufacturing and testing standards are in accordance with CNS 13390 or IEC 60076-11 specifications unless otherwise specified by the customer.
  3. Applicable conditions
    a.Load: continuous rated load.
    b.Location of use: indoor type below 1000 meters above sea level.
    c.One week temperature: maximum 40 ° C, average 30 ° C per day.
    d.Relative humidity: up to 100%.
  4. Transformer characteristics
    a.Rated continuous output capacity: The transformer capacity in this specification refers to the continuous output capacity under the specified temperature rise conditions.If forced air cooling, the output capacity can be increased by 25-40%. The size of the conductor used, including the connection terminals and accessories, is designed with the highest rated capacity.
    b. Type: double winding, self-cooling, indoor type, resin type dry winding.
    c. Rated voltage and wiring: according to customer requirements or primary side: △ wiring, secondary side: △ or Y wiring.
    d.High-voltage coil tap voltage: according to customer requirements or rated voltage ± 2 × 2.5%.
    e. Polarity: Reduced polarity (for single phase).
    f. Winding insulation level and voltage resistance:

    g. Insulation material heat-resistant grade: F-type (or H-grade) heat-resistant grade insulation material is used for the mold dry type.
    h. Temperature rise limit: The average winding temperature rise measured by resistance method under the ambient temperature of 40 ℃ and the rated load, F-class insulation shall not exceed 100 ℃, and H-class insulation shall not exceed 125 ℃.
    i. Refer Transformer performance list (at pf = 1, 75 ° C).
    j. The above performance is a reference value.All performances should be marked based on the final approval information or test report.
    k. For other specifications transformers, relevant technical data will be provided separately according to customer requirements.
  5. Transformer Construction
    a.core:The cold-rolled directional silicon steel sheet material with high magnetic permeability and low iron loss is laminated with V-notch 5 steplap core method. The surface of the completed core is additionally coated with special resin to prevent moisture And anti-corrosion. The core is grounded and visible to the base.
    b.fastener: The core is fixed with Slot iron and screws of sufficient strength. The structure of the core and Slot iron is to be solid and stable, and to avoid subjecting the core to external stress to affect iron loss and noise. All fixed metals other than the core have anti-rust treatment.
    c.coil: High-voltage coils use electrical copper (or aluminum) conductors. The coil insulation is reinforced with a special glass fiber resin, and the resin is poured in an automated pouring equipment and under vacuum. The coil after the resin is poured is cured by heating.Partial discharge test is performed on the high-voltage coil after molding to confirm that it does not contain any Cavity & Air Void so that it has the best electrical and mechanical characteristics.Low-voltage coils are made of copper (or aluminum) conductors and pre-impregnated resin materials (Pre-Impregnated) wound on a mold at the same time and heat-hardened. The resin is poured above and below the coil to increase its strength.After completion, the high and low voltage coils are moisture-proof, non-flammable, non-combustible, and automatically extinguished.The ends of the high and low voltage coils and the upper and lower slot irons are fixed with a support with elastic gaskets to tighten the coil and absorb the thermal expansion and contraction of the coil.
    d.Terminal: Except for the lead-out terminals of the high-voltage coil, the connecting wires of the live parts are covered with heat-resistant insulation, and all lead-out terminals adopt NEMA standard copper connectors. The terminals of the low-voltage coil are led out by a bus, and the terminal head of the bus should comply with the customer (or NAME standard).
    e.Tap changer: The high voltage side winding of the transformer is provided with taps that can adjust the voltage under no voltage and current. These taps are drawn from the winding surface so that the voltage of the tap can be switched after the power is cut off (under no voltage state).
    f.Nameplate
    (1) Type
    (2) Phase sequence
    (3) Number of phases
    (4) Wiring diagram
    (5) Rated capacity (kVA)
    (6) Manufacturing number
    (7) Rated frequency (Hz)
    (8) Approximate weight (kg)
    (9) Rated voltage
    (10) Tap voltage
    (11) Base Impact Insulation Level (BIL)
    (12) Ambient temperature
    (13) Coil temperature rise
    (14) Manufacturer name
    (15) Impedance voltage
    (16) Date
    g.Accessories
    (1) Stainless steel nameplate.
    (2) The base.
    (3) Ground connector
    (4) Lifting ears.
    h.Select accessories
    (1) Wheels.
    (2) The fan.
    (3) Thermometer.
    (4) Digital temperature monitor. (The transformer has a three-stage (fan start, warning and trip) temperature controller, which provides contact wiring and is led by the customer.)
    (5) Shockproof rubber.
    (6) Earthed screen between primary and secondary windings.
    i.Outer box protection: (if needed)
    (1) For IP20, it is only for indoor use.
    (2) For IP23 or above, it can be used outdoors.
  6. Test: The following tests are performed before the transformer leaves the factory.
    1.Routine test items (each must be tested)
    (1) Resistance measurement.
    (2) Turn ratio measurement.
    (3) Polarity and phase sequence test.
    (4) Excitation current and no load loss test.
    (5) Impedance voltage and load loss test.
    (6) AC test.
    (7) Induced voltage test.
    (8) Partial discharge test. (Above 3.3kV)
    2.Type test (according to customer's specification but additional charge)
    (1) Noise test.
    (2) Temperature rise test.
    (3) Impulse voltage test.
    3.test report: Three complete test reports are provided when leaving the factory, which contain information on the test projects listed above.
  7. Warranty: Store for 18 months after delivery or run for 12 months under normal use.
  8. Factory Certification: ISO 9001, ISO 14001, OHSAS 18001, UL 1561, TAF17025 Laboratory
  9. Delivery method: Domestic - truck up to the ground / Foreign – CIF

Keywords: Cast Resin Transformer  Cast Resin Transformers   

Enquire Now!
Company Name CHU LEI ELECTRIC CO., LTD.
Country/Region Taiwan
City Taoyuan City 330
Address No.18, Ln. 50, Daren Rd., Taoyuan Dist.
Telephone +886-3-3639519
Fax +--
Contact Person
Website www.powertransformer.com.tw