Testing
Conditions:
Testing
Pressure........................ 225 psi (1.55Mpa)
Temperature of Testing
Solution.................. 25centigrade
Concentration of Testing
Solution (NaCl)........ 2000ppm
pH Value of Testing
Solution................. 7.5
Recovery Rate of Single
Membrane Element...... 15%
Operation limits and
conditions
Max. Working
Pressure....................... 600psi (4.14Mpa)
Max. Feedwater
Flow..................... 75gpm (17 m3/h) (for 8040)
16gpm (3.6 m3/h) (for
4040)
Max. Feedwater
Temperature................... 45centigrade
Max. Feedwater
SDI........................ 5
Residual chlorine Concentration
of Feedwater......... <0.1ppm
pH Range of Feedwater during
Continuous Operation...... 3~10
pH Range of Feedwater during
Chemical Cleaning...... 2~12
Max. Pressure Drop of Single
Membrane Element....... 15psi (0.1Mpa)
Dimensions of FO
membrane element